論文
著者 | 共同著者 | 論文名 | 雑誌名 |
---|---|---|---|
Takuya Yabe | First measured optical image of Cerenkov-light in water during irradiation of neutron beam from boron neutron capture therapy (BNCT) system | Radiation Measurements Volume 146, August 2021, 106633 https://doi.org/10.1016/j.radmeas.2021.106633 | |
Hitomi Koyanagi | Yoshinori Tsutsumi, Maki Endo, Yasushi Furukawa, Shinji Abe |
Computed tomography imaging using split-bolus contrast injection with volume scan of aortic root and heart for preoperative evaluation of transcatheter aortic valve implantation | Heart Vessels. 2022;37(1):132-141. https://doi.org/10.1007/s00380-021-01899-8 |
Naotoshi Fujita | Shinji Abe | Variation in thyroid volumes due to differences in the measured length or area of the cross-sectional plane : A validation study of the ellipsoid approcimation method using CT images | J Appl Clin Med Phys. 2021;22(4):15-25. https://doi.org/10.1002/acm2.13125 |
Yutaka Kato, Kuniyasu Okudaira |
Youta Nagai | Evaluation of system-related magunetic resonance imaging geometric distortion in radiation therapy treatment planning : two approaches and effectiveness of three-dimentional distortion correction | Nagoya J Med Sci. 2022;84(1):29-41. https://doi.org/10.18999/nagjms.84.1.29 |
Yutaka Kato | Yumiko Noguchi, Kuniyasu Okudaira | Hybrid 3D T1-weighted gradient-echo sequence for fiducial marker detection and tumor delineation via magnetic resonance imaging in liver stereotactic body radiation therapy. | Phys Med. 2022;95:9-15. https://doi.org/10.1016/j.ejmp.2022.01.003 |
Takeshi Kamomae | Kuniyasu Okudaira, Fumitaka Kawabata, Yutaka Kato | Dosimetric impacts of beam-hardening filter removal for the CyberKnife system | Phys Med. 2021;86:98-105. https://doi.org/10.1016/j.ejmp.2021.05.011 |
Masako Kataoka | Yutaka Kato | Ultrafast Dynamic Contrast-enhanced MRI of the Breast: How Is It Used? | Magn Reson Med Sci. 2022;21(1):83-94. https://doi.org/10.2463/mrms.rev.2021-0157 |
Tetsuya Tsukada | Takashi Mizuno | Comparison of hemodynamic stress in healthy vessels after parent artery occlusion and flow diverter stent treatment for internal carotid artery aneurysm | J Neurosurg. 2021;136(3):619-626. https://doi.org/10.3171/2021.2.JNS204185 |
Shinji Naganawa | Kazushige Ichikawa | MR Imaging of endolymphatic hydrops : Utility of iHYDROPS-Mi2 cmbined with deep learning reconstruction denoising | Magn Reson Med Sci. 2021;20(3):272-279. https://doi.org/10.2463/mrms.mp.2020-0082 |
Shinji Naganawa | Yutaka Kato | Intracranial Distribution of intraveneously administered Gadolinium-based contrast agent over a period of 24 Hours : Evaluation with 3D-real IR Imageing and MR Fingereprinting | Magn Reson Med Sci. 2021;20(1):91-98. https://doi.org/10.2463/mrms.mp.2020-0030 |
Shinji Naganawa | Kazushige Ichikawa | MR imaging of endolympatic hydrops in Five minutes | Magn Reson Med Sci. 2021;10.2463/mrms.ici.2021-0022. https://doi.org/10.2463/mrms.ici.2021-0022 |
Ryota Hyodo | Takashi Mizuno, Kazushige Ichikawa | Assessing the complicated venous hemodynamics and therapeutic outcomes of Budd-Chiari Syndrome with respiratory-gated 4D Flow MR Imaging duaring the expiratory and inspiratory phases | Magn Reson Med Sci. 2021;10.2463/mrms.ici.2021-0110. https://doi.org/10.2463/mrms.ici.2021-0110 |
Kentaro Suzuki | Fumitaka Kawabata, Kazuma Sugita, Kuniyasu Okudaira, Masaki Mori, Shinji Abe |
Development of an X-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance | Phys Med. 2021;91:121-130. https://doi.org/10.1016/j.ejmp.2021.10.017 |
Ryota Hyodo | Takashi Mizuno, Kazushige Ichikawa | Portal vein stenosis following liver transplantation hemodynamically assessed with 4D-flow MRI before and after portal vein stenting | Magn Reson Med Sci. 2021;20(3):231-235. https://doi.org/10.2463/mrms.ici.2020-0057 |
Ryota Hyodo | Takashi Mizuno, Kazushige Ichikawa | Time-resolved 3D cine phase-contrast magnetic resonance imaging (4D-flow MRI) can quantitatively assess portosystemic shunt severity and confirm normalization of portal flow after embolization of large portosystemic shunts | Hepatol Res. 2021;51(3):343-349. https://doi.org/10.1111/hepr.13616 |
Takafumi Otuka | Takeshi Uemura, Takashi Sakai |
Streak Metal Artifact Reduction Technique in Cone Beam Computed Tomography Images after Endovascular Neurosurgery | Neurol Med Chir (Tokyo). 2021;61(8):468-474. https://doi.org/10.2176/nmc.oa.2021-0014 |
発表
発表者名 | 演題名 | 学会名 |
---|---|---|
加藤 裕 | Performance Evaluation of Turbo Gradient- and Spin-echo Diffusion-weighted Pulse Sequence with BLADE Trajectory Technique for ADC Values and Susceptibility Distortions: A Phantom Study | 第77回日本放射線技術学会総会学術大会2021.4(横浜) |
加藤 裕 | MR FingerprintingにおけるSpatiotemporal residual mapを用いた液体の動きの影響 | 第49回日本磁気共鳴医学会大会2021.9(横浜) |
加藤 裕 | MRI検査用金属探知機の特性評価に関する研究 | 第49回日本放射線技術学会秋季学術大会2021/10/15~17 (熊本/Web開催) |
末澤 正太郎 | 前立腺がん永久刺入治療用I-125シードに対するバッチアッセイに向けた基礎検討 | 日本放射線腫瘍学会小線源治療部会第23回学術大会 2021/5/21~22 (Web開催) |
杉田 和真 | Use of 3D printer to create a electron shielding block with Tungsten-containing Thermoplastic rubber | 第49回日本放射線技術学会秋季学術大会 2021/10/15~17 (熊本/Web開催) |
西村 拓真 | PET/CTにおける通常撮影前に行う予備撮影の至適撮影条件の検討 | 第13回中部放射線医療技術学術大会 2021/11/20~26(Web開催) |
富板 佑香 | ステレオガイド下マンモトーム生検における撮影条件の検討 | 第13回中部放射線医療技術学術大会2021/11/20~26(Web開催) |
瀬野 貞博 | Evaluation of the usefulness of a synchronous current comparison method in high energy electron beams | The 9th Korea-Japan Joint Meeting on Medical Physics 2021/9/9~10 |
植村 武司 | IRにおける灌流チューブ内 空気混入警報システムの開発 | 第37回NPO法人日本脳神経血管内治療学会学術集会(JSNET2021) 2021/11/25~27(福岡/Web開催) |
植村 武司 | IRにおける灌流チューブ内空気混入警報システムの開発 (第2報) | 第33回公益社団法人愛知県診療放射線技師会学術大会 2022/3/6(Web開催) |
松本 拓也 | X線CT画像における植込型心臓電気デバイスリードから発生する金属アーチファクトの評価 | 第33回公益社団法人愛知県診療放射線技師会学術大会 2022/3/6(Web開催) |
小柳 仁美 | TAVI 術前 CT における320列 CT による分割ボーラス注入法の有用性 | 第11回日本経カテーテル心臓弁治療学会学術集会 2021/8/27~28(Web開催) |